Description
Body Material:
• Steel Frame Structure
• Digital Thermal Printed Sheet
• Acrylic Round support board or Plastic Sheet
Working area:
• Working area: 60*40*15 cm
• Frame size: 100 * 65 *15 cm
Safety Circuit Breaker
• Operating voltage: 440V.
• Cutting power (Icn): 10000A (10kA) (Ics-75% icn).
• Characteristic curve: C.
• Mechanical life: 20000 operations.
• Electrical life: 10000 operations.
• Earth-Leakage Protection.
• Auto Short-Circuit Management
• ERR Tripping sense Current 20mA
System Inverter:
• Type: DC/AC Inverters
• Output Type: Single
• Output Current: as per voltage and power
• Output Frequency: 50Hz or 60Hz
• Size: 284*200*60mm
• Weight: 3.1KGS
• Product name: Pure Sine Wave Inverter Board
• Rated Power: 3000W
• Peak power: 6000W
• Output waveform: Pure Sine Wave
• Efficiency: 90%
• Phase: Single Phase Power Inverter Compressor:
• Power: 1/2HP,
• Single-phase 220V
• Control Box AC Panel Meter:
• Measurement accuracy: 1%
• Measuring range: AC voltage: AC80-300V, AC current: 0.1- 100A
• Power consumption: 0.2VA
• Measuring speed: about 2 times per second
• Overall dimensions: 70 * 40 * 39mm
• Installation size: 68 * 38mm (embedded installation)
• The instrument is only suitable for pure AC 50-60HZ of the mains power Connector:
• Female Connector Diameter 13mm
• Male Connector Diameter 4.5mm Parameters:
• Steel structure mounted on wheels, painted and treated in the oven
• Thermal printed schematic diagram of the two alternative circuits, with warning LEDs
• 7000 BTU/h split-type unit with inverter, including
• Variable-speed hermetic compressor
• forced air condenser
• 3-speed fan evaporator with deflector
• Refrigerant expansion through capillary tube
• 4-way valve
• Remote control for adjustment
• On-off valves
• Valve for plant vacuum, refrigerant charging and recovering
• Full set of instruments for data acquisition, including:
• Flow meters –high- and low-pressure gauges
• 4 electronic thermometers with Pt100 probes to be inserted in various test points
Reviews